Cardiac ultrasound image analysis software research highlighted at ase 2015. This novel method of documentation of myocardial motion. Speckle tracking echocardiography ste is a rapidly growing field in echocardiography allowing us to study the deformation of the myocardium. Speckle tracking masterclass compendium 123sonography. Tissue doppler and speckle tracking collates the latest research into a specific, indepth resource. This fast and easytouse interface is designed specifically for stress echo exams. Aug 26, 2016 tissue tracking technology of routinely acquired cardiovascular magnetic resonance cmr cine acquisitions has increased the apparent ease and availability of noninvasive assessments of myocardial deformation in clinical research and practice. Pointofcare poc echocardiography has been wellestablished as a rapid and noninvasive tool for emergency providers ep to identify acute myocardial injury. For more advanced analysis, speckle tracking algorithms have been developed that harness the high temporal and spatial resolution of ultra high frequency ultrasound. Speckle tracking echocardiography is a new simple, easy and inexpensive method with the potential of becoming the reference clinical bedside tool for the evaluation of lv function shortening, thickening and torsion. Strain analysis by speckle tracking echocardiography natesa g. It was an important first step in the development of generally accepted tools for qa of speckle tracking echocardiography. Global and regional longitudinal strain glsrls assessed by twodimensional speckle tracking echocardiography 2dste are considered reliable indexes of leftventricular lv function and myocardial viability in chronic ischaemic patients when compared with delayedenhanced cardiac magnetic resonance decmr.
Speckle tracking allows you to look at the timing of regional contraction. Speckle tracking echocardiography ste is a new, noninvasive method for the assessment of left ventricular lv global and regional function. A number of ultrasound systems are now available that offer ste capabilities. Conventional 2d echocardiography can measure basic lv function i. It measures lv regional and global deformations in response to force as a marker of contractility and elasticity. Strain analysis by speckle tracking echocardiography. Two dimensional 2d speckle tracking echocardiography ste is a promising new imaging modality. It tracks individual blood cells on ultrasound as they flow through the heart on dynamic, 4d echo. Oct 01, 2017 strainbased imaging techniques and specifically speckle tracking echocardiography have been shown to have clinical utility in a variety of settings. Different software from different manufacturers derive gls differently. Recent advances in echocardiography technology daic. Pdf introduction to speckle tracking in cardiac ultrasound.
First introduced as postprocessing of tissue doppler imaging velocity converted to strain and strain rate, strain imaging has more recently also been derived from digital speckle tracking analysis. Speckletracking imaging, principles and clinical applications. Possibility to edit contours manually with re tracking. These measures can be useful in the evaluation of several cardiac motion abnormalities. Its widespread availability thanks to the fact that this technology can in principle be applied on images that are part of every cmr or. Echocardiographic strain imaging, also known as deformation imaging, has been developed as a means to objectively quantify regional myocardial function. Effects of frame rate on twodimensional speckle trackingderived measurements of myocardial deformation in premature infants. Speckle tracking echocardiography radiology reference.
Regional myocardial strain analysis via 2d speckle. Watch a video showing these and other vendors echo advanmcements displayed at acc. Definitions for a common standard for 2d speckle tracking. With the 2d speckle tracking software from each vendor, radial, circumferential and longitudinal strain were measured using an 18. Epsilon imagings echoinsight software used in four studies assessing echo analysis. This video, provided in partnership with the american society of echocardiography ase, is titled strain fundamentals made easy strain in routine clinical practice. Possibility to edit contours manually with retracking. Gain a deep knowledge of strain rate imaging and where it can be applied with the selfpaced online diploma course. In the targeted left ventricular lead placement to guide cardiac resynchronisation therapy target trial, lv lead placement guided by speckle. Intraventricular vortex revealed by speckle tracking without administration of contrast agent. Speckle tracking software packages should commonly report lagrangian strain s.
The study concluded fourchamber longitudinal strain. Evaluating fetal heart and ruling out congenital heart anomalies is complicated at 1820 weeks. Postprocessing of echo images to analyze deformation has become readily. Speckletracking echo helps guide crt lead placement. Pdf the speckle tracking imaging for the assessment of. Echocardiographic assessment of myocardial strain jacc. Advanced cardiac imaging using vevo strain early detection of myocardial deformation using speckletracking software. The addition of speckle tracking software to poc echocardiography is a novel technology that detects the magnitude, or percent strain, of myocardial deformation. Similar to tissue doppler imaging tdi, it permits offline calculation of myocardial velocities and deformation parameters such as strain and strain rate sr. The book focuses on how to use advanced cardiac imaging techniques in everyday clinical practice, presenting relevant material in a logical format. Feb 23, 2017 the following are areas for potential future improvement in or greater adoption of speckletracking echo. The endocardial border and the myocardium was then automatically tracked framebyframe by the vvi software throughout the cardiac cycle. Speckle tracking echocardiography ste for detection of lv myocardial strain is a novel cardiac imaging technique assessed by echocardiography.
May 26, 2017 this video, provided in partnership with the american society of echocardiography ase, is titled strain fundamentals made easy strain in routine clinical practice. All these systems use their own proprietary software for myocardial deformation imaging but the basic steps involved are same. For the cmt tracking algorithm, i have done a real test on iphone5s, tracking the effect is beyond imagination, in comparison to me, ct, color, tra. Ultrasound system sonoace r7 samsung healthcare global. How and why to measure lv myocardial strain duration. Collaboration between vendors could serve to reduce intervendor variability. This video lecture is only available for subscribers. In this retrospective c main outcome measures were circumferential and longitudinal strain and strain rate as prognostic and diagnostic markers. Speckle tracking echocardiography radcliffe cardiology. It is well accepted that these parameters provide important insights into systolic and diastolic function, ischaemia, myocardial. We present an acute canine model that integrates a complex sonomicrometer array with microsphere blood. Similar to mri tagging, speckle tracking follows features. Qlab ultrasound cardiac analysis philips ultrasound. Speckle tracking for acute coronary syndrome ultrasound gel.
Global longitudinal strain for lv function american. Quantitative regional strain analysis by speckle tracking echocardiography ste may be particularly useful in the assessment of myocardial ischemia and viability, although reliable measurement of regional strain remains challenging, especially in the circumferential and radial directions. Cardiac ultrasound image analysis software research. Speckle tracking masterclass compendium introduction. Edited by internationally recognized experts in cardiac imaging, myocardial imaging. If you havent heard of speckle tracking on echocardiography it is a pretty cool idea see this brief video if you have no idea what this is. However, common features involve view selection, defining endsystole, tracing. Segmentorientated analysis of twodimensional strain and.
Speckle tracking echocardiography describes the semiautomated analysis of grey scale bmode echocardiographic studies in which the spatial translocation of derived functional units speckles allows quantitative analysis of myocardial function speckle tracking constitutes a subset of deformation imaging, which is utilized in the assessment of left ventricular function in the setting of. Strainbased imaging techniques and specifically speckletracking echocardiography have been shown to have clinical utility in a variety of settings. Autoplay when autoplay is enabled, a suggested video will automatically play next. Before the advent of ste, the only technique for angleindependent. Speckletracking echocardiography ste is a recently developed technique for the characterization and quantification of myocardial deformation.
Apr 26, 2018 watch a video showing these and other vendors echo advanmcements displayed at acc. Strainbased imaging techniques and specifically speckle tracking echocardiography have been shown to have clinical utility in a variety of settings. At the 2017 transcatheter cardiovascular therapeutics tct meeting, ge showed its innovative blood speckle imaging bsi technology on the e95. Strain echocardiography by speckle tracking and tissue. In the fields of cardiology and medical imaging, speckle tracking echocardiography ste is an echocardiographic imaging technique that analyzes the motion of tissues in the heart by using the naturally occurring speckle pattern in the myocardium or blood when imaged by ultrasound. This technique is being embraced and increasingly adopted in many echocardiography laboratories worldwide. Practical strain imaging for meeting todays challenges in stress echo. The compassion trial is showing promising early results, and our study suggests that speckletracking echocardiography ste may be a more sensitive tool than traditional echo or mri to predict outcomes in these patients, said primary.
Speckle tracking echocardiography is promising tool in assessing regional and global right ventricular deformation in different directions in terms of both amplitude and timing, with the advantage of being less affected than tissue doppler imaging by overall heart motion figure 10. Initially used as a research tool, many laboratories now include ste. Principles of cardiovascular magnetic resonance feature. Improved tracking and border recognition may lead to shorter analysis times. The vvi algorithm includes speckle tracking, global motion coherence, and consistency of periodicity between cardiac cycles, which are described in detail in the producers patent us 6. Booked a designated carrier has been assigned to move this freight order. Global and regional longitudinal strain assessed by two. By allowing measurement of the different components of myocardial deformation, it provides information which is not available with any of the currently used echocardiographic parameters, including left ventricular ejection fraction lvef. Speckle tracking echocardiography is a nondoppler technique that applies computer software analysis of images generated by conventional ultrasound techniques. Strain is a complex derivative of doppler imaging and is a more direct measurement of. The doppler ultrasound signal generates artifacts due to random reflections, called speckles. Aug 06, 2019 speckle tracking software allows those points to be tracked over time. This condition is not uncommon and affects one out of every 110 babies around the world.
Twodimensional speckle tracking provides valuable information for regional wall motion abnormalities. He is also a codirector of the echo ase asean conference. Tissue tracking technology of routinely acquired cardiovascular magnetic resonance cmr cine acquisitions has increased the apparent ease and availability of noninvasive assessments of myocardial deformation in clinical research and practice. The ultrasonologist can now assess the size, shape, and function of the fetal heart in less than 3 minutes with the ge healthcare new fetalhq software.
Study shows promise for speckletracking echo after. Gls is derived from speckle tracking, and analyzed by postprocessing of apical images of the lv. Based on 2d speckle tracking technology, cmq stress provides a method for assessing global, regional, and local cardiac function at rest and peak exercise. This is the first study in which all currently commercially available 2d speckle tracking software packages have been tested on synthetic ultrasound data. Jan 26, 2010 speckle tracking echocardiography ste is a more recent technique that provides a global approach to left ventricular myocardial mechanics, giving information about the three spatial dimensions of cardiac deformation.
Iacopo fabiani, nicola riccardo pugliese, veronica santini, lorenzo conte and vitantonio di bello october 19th 2016. Speckle tracking is a technology that allows for an accurate quantification of the motion of the myocardium throughout the cardiac cycle. This chapter will provide an overview on dyssynchrony and how the speckle tracking curves can help you to detect, and even quantify, the magnitude of dyssynchrony. Up next speckle tracking masterclass your introduction to strain rate imaging duration. Twodimensional speckle tracking for the assessment of. Speckle tracking echocardiography in acute myocarditis. Natural strain rate sr n is commonly reported when using tissue doppler, but can also be derived from speckle tracking by conversion from the lagrangian strain rate.
Deformation imaging by echocardiography is a wellestablished research tool which has been gaining interest from clinical cardiologists since the introduction of speckle tracking. The speckle tracking imaging for the assessment of cardiac resynchronization therapy start study article pdf available in circulation journal 793. Analysis of cardiac motion can be very challenging and prone to significant variability. Feasibility and accuracy of speckle tracking echocardiography. Ste offers the opportunity to track myocardial deformation independently of both cardiac translation and the insonation angle. Greater automation may lead to more widespread adoption of the technique. Myocardial strain measured by speckletracking echo. The purpose of this study was to determine the diagnostic value of left ventricular longitudinal strain and torsion to diagnose coronary artery disease during dobutamine stress echocardiography. This can be measured in multiple planes, but when considering the left ventricle, the longitudinal plane is the first to show impairment, and therefore is often used to measure strain.
Does the software measure full thickness strain, a. Practical strain imaging for meeting todays challenges in. Echo studies were performed before and after induction of therapy. The following are areas for potential future improvement in or greater adoption of speckletracking echo. Strain echocardiography and speckle tracking temple. Jun 27, 2012 to evaluate 2dimensional speckle tracking echocardiography as a diagnostic and prognostic tool in patients with acute myocarditis. The role of speckle tracking echocardiography in assessment of lipopolysaccharideinduced myocardial dysfunction in mice. Apr 28, 2015 vivid 7 2d strain echokardiographie animation.
Transthoracic speckle tracking echocardiography for the. Therefore, ste can be used to study dyssynchrony in potential crt candidates. Study shows promise for speckletracking echo after transcatheter pulmonary valve implantation. The samsung ultrasound system sonoace r7, with samsungs outstanding 2d performance, sensitive pulsed wave, color doppler and 3d4d diagnostic technology, redefines how to meet the essential needs of users. The sonoace r7 offers 3d xi, emotion marker, elastoscan, strain, stress echo and many additional tools for diagnosis in multiple applications. The agreement between 3d, standard 2d and triplane 2d speckle tracking.
514 983 1510 209 315 791 769 76 596 237 721 156 1407 100 1258 668 880 691 736 786 301 116 1353 975 1255 1203 729 266 1492 339